| Duro A1 | Duro A5 | Duro B1 | Duro B5 | |
|---|---|---|---|---|
| System | 1-bay quick-charger for regular batteries |
5-bay quick-charger for simultaneous charge of 5 batteries | 1-bay quick-charger for SMBus batteries; also charges regular batteries | 5-bay quick-charger for simultaneous charge of 5 regular and SMBus batteries |
| Battery interface | The chargers are factory configured for the battery type. Customer specified. | |||
| Chemistries | Nickel-cadmium (NiCd), nickel-metal-hydride (NiMH) and lithium-ion (Li-ion). | |||
| Charge protocol | Nickel-based: Constant current; charge termination:
dT/dt (rate-of-temperature increase); 1°C/min. rise, NDV 8-10mV/cell;
plateau timer; trickle charge of 0.05C when ready. Lithium-based: Constant voltage, current limit; charge termination on current drop to 0.05C. |
|||
| Temperature management | Nickel-based: Trickle charge if below 0°C, normal
charge when warm Lithium-based: No charge if below 5°C, resumes charge when warm No charge for all chemistries above 50°C; resumes when cooled down to 45°C. |
|||
| Battery mAh/V | 500mAh - 8000mAh | |||
| Low-V version High- V version |
3.60 - 7.20V 8.40 - 14.40V |
3.60 - 7.20V 8.40 - 14.40V |
Special order 9.60 - 14.40V |
Special order 9.60 - 14.40V |
| Charge time | Nickel-based chemistries: 90 minutes typical; longer
on larger batteries Lithium-based chemistries: 3h typical; longer on larger batteries |
|||
| Discharge power | Not available | Not available | Not available | 1A, 15W max each for bays 1 & 2 |
| Light signals | Charging: Flashing green Ready: Solid green Fail: Solid red |
Same, red/green discharging; flashing red hint to calibrate | ||
| Electrical | 18 watts external AC power adapter, (90-250 VAC, 47-63 Hz) |
90 watts external AC power adapter, (90-250 VAC, 47-63 Hz) | 30 watts external AC power adapter, (90-250 VAC, 47-63 Hz) | 150 watts external AC power adapter, (90-250 VAC, 47-63 Hz) |
| Vehicle mount | Charges 3.6 - 7.2V batteries from 12VDC vehicular power source | |||
| Approvals | CSA 60950, UL60950, EN 60950 for safety and FCC Part 15 Class A, EN55022 Class A for EMI, and EN61000-3-2, EN61000-3-3 and EN61000-4-2, -3, -4, -5, -6, -11 for EMC. RoHS and WEE compliant | |||
| Environmental | Operating temperature: 0°C to +40°C (32°F
to +104°F) Storage temperature: -30°C to +70C (-22 to +158°F) |
|||
Physical
Length Width Height Weight |
232.4 mm (9.15”) 127 mm (5”) 57 mm (2.24”) 0.4 kg (0.88 lb) |
520.7 mm (20.5”) 232.2 mm (9.14”) 57 mm(2.24”) 3.25 kg (7.16 lb) |
232.4 mm (9.15”) 127 mm (5”) 57 mm (2.24”) 0.4 kg (0.88 lb) |
520.7 mm (20.5”) 232.2 mm (9.14”) 57 mm(2.24”) 3.25 kg (7.16 lb) |
| Warranty | Cadex warrants the analyzer against defective materials and workmanship for a period of one (1) year from the original purchase date. | |||