Automated programs support all battery needs
The 18 service programs are grouped into
Basic,
Advanced and
Custom.
Basic Programs
Advanced Programs
- Self-Discharge – Determines the rate at which a battery loses charge.
- Life Cycle – Counts number of charge/discharge cycles before the battery capacity drops to selected target level.
- Discharge Only – Discharges battery for storage; tests chargers.
- Extended Prime – Applies a 16-hour trickle charge, followed by Prime. Prepares difficult to charge batteries.
- OhmTest – Measures internal battery resistance in 6 seconds.
- Runtime – Simulates field application
with three adjustable load currents and time intervals.
- Boost – Reactivates seemingly dead batteries that have been discharged too low.

- QuickTest™ – Provides battery state-of-health in 3 minutes. Needs specific battery matrix.
- Q-Learn – Provides initial QuickTest™ matrix by scanning a good battery. Service time is 3-5 minutes.
- Learn – Improves QuickTest™ matrix by scanning batteries with different state-of-health status. Service time is 3-8 hours per battery.
Custom programs
Four separate Custom programs allow
user-defined programs composed of charge, discharge, recondition, wait
and repeats. The programs follow a different path if a certain condition
occurs.